New Machinery


Forging Industry Association logo

Save

Save

Share:

800 MW GE / Alstom Combined Cycle Gas Turbine
50 Hz Power Plant operates on Natural Gas Re:25937

25937

This is an 810 MW (2 x 405 MW, ISO) Combined Cycle Power Plant comprised of two (2) identical streams of 1+1+1 configuration.

Each stream has one 9FA Gas turbine from GE/USA, one Steam Turbine Generator from Alstom/Germany & one HRSG along with associated auxiliaries & the balance of equipment which fully equips a complete Plant.

The plant was commissioned in Oct 2015 and is currently not in operation as there is no gas supply. It is currently under preservation as per OEM norms.

Periodic maintenance and technical support for the Gas and Steam Turbines is on going and all plant and equipment will receive warranties and guarantees for performance from the respective OEM’s.

Used Power Plants
Specifications
Rating
800 MW
800 MW
 
Type
Steam Turbine
Steam Turbine
 
Manufacturer
GE / Alstrom
GE / Alstrom
 
Model
9FA/HD1CK+MDG160
9FA/HD1CK+MDG160
 
Fuel
Natural Gas
Natural Gas
 
Hz
50
50
 
Age
2015
2015
 
Ref #
25937
25937
 
Note

Additional Information:

Plant Capacity:

2 X 405.40 MW at ISO conditions

2 X 383.78 MW at site conditions

Gross Heat Rate – 1515 Kcal/Kwh on LHV basis at ISO conditions

Auxiliary power consumption < 3%

Fuel requirement: Natural Gas ~ 1.64 mmscmd at 9500 Kcal/scm, HHV at site conditions

Water Consumption 25000 cu.m per day

Emission Limits

Provided with Dry Low NOx burners with NOx and CO limits as 35 ppmv & 15 ppmv @ 15% O2 resp

Supplementary Duct Firing 33 MW capacity

Start up and Controls • Islanding capability to meet the house load

• Capable to reach full load in 90 min. under hot conditions

• Possible to start GT from local as well as remote

• Capable of quick response to unscheduled demand

Gas Turbine Running Hours

Unit #1 -2790 Fired hours

(Hot Gas Path Inspection at 24000 hrs. & Major inspection at 48000 hrs.)

Unit #2 -1547 Fired hours

(Hot Gas Path Inspection at 24000 hrs. & Major inspection at 48000 hrs.)

Major Equipment Component List:

(2) x 240 MW Gas Turbines

(2) x 214 MVA, Gas Turbine Generators, 0.80 P.F

(2) x 144 MW Steam Turbines

(2) x 169.65 MVA Steam Turbine Generators, 0.85 P.F

(2) No. Vertical, Triple pressure , Reheat type HRSG's

(2) x 277 MVA Power Transformer for GTG 's

(2) x 170 MVA Power Transformer for STG's

(2) x 28 MVA Unit auxiliary transformers

(2) X 1.01 MVA EDG's

(4) X 14260 m3/hr CW pumps

(4) X 570m3/hr Condensate Extraction pumps

(4) X 410 m3/hr HP/IP Boiler Feed Pumps